Human CD42b/GP1BA Protein
Catalog No: CD42B-HF001
- Species
- Human
- Expression System
- HEK293
- Tag
- an hFc (IgG1)
- Activity
- Activity verified
Product overview
Recombinant Human CD42b/GP1BA Protein is expressed in HEK293 cells with an hFc (IgG1) tag at the C-terminus. It contains amino acid residues His17-Leu531 (UniProt accession: P07359).
Product Details
- Molecular Aliases
- GP-Ib alpha; GPIb-alpha; GPIbA; GP1BA; BDPLT1; BDPLT3; BSS; CD42B; CD42b-alpha; DBPLT3; GP1B; VWDP; BP1BA; MGC34595
- Protein Length
- His17-Leu531
- Expression System
- HEK293
- Theoretical Molecular Weight
- The protein has a predicted MW of 82.47 kDa. Due to glycosylation, the protein migrates to 130-170 kDa based on Bis-Tris PAGE result.
- Purity
- > 95% as determined by Bis-Tris PAGE > 95% as determined by HPLC
- Endotoxin
- Less than 0.1 EU per μg by the LAL method.
- Buffer / Formulation
- Lyophilized from 0.22 μm filtered solution in PBS, 100mM L-Arginine (pH 7.4). Normally 8% trehalose is added as protectant before lyophilization.
- State
- Lyophilized
- Storage Conditions
- -20 to -80°C for 12 months as supplied from date of receipt. -80°C for 3 months after reconstitution. Recommend to aliquot the protein into smaller quantities for optimal storage. Please minimize freeze-thaw cycles.
- Reconstitution Advice
- Dissolve the lyophilized protein in distilled water. Please refer to the Certificate of Analysis for detailed instructions.
Data Display

Human CD42b on Bis-Tris PAGE under reduced condition. The purity is greater than 95%.

The purity of Human CD42b is greater than 95% as determined by SEC-HPLC.

Immobilized Human CD42b, hFc Tag at 0.5μg/ml (100μl/well) on the plate. Dose response curve for Anti-CD42b Antibody, hFc Tag with the EC50 of 21.1ng/ml determined by ELISA. (QC Test)
Background
Absence of the CD42 complex leads to the Bernard-Soulier syndrome (BSS), which is a bleeding disorder characterized by thrombocytopenia and giant platelets. So far, mutations have been found in the genes encoding CD42a, CD42b and CD42c in patients with BSS**.
References
- Clemetson KJ,McGregor JL,James E,Dechavanne M,Luscher EF Characterization of the platelet membrane glycoprotein abnormalities in Bernard-Soulier syndrome and comparison with normal by surface-labeling techniques and high-resolution two-dimensional gel electrophoresis. J Clin Invest 1982 70:304 Note: HPLC results always come from liquid protein, due to absorption peak interference of trehalose in lyophilized powder.
Have questions about this product?
Our technical team can help with product selection, application questions and order support.