Human CD42b/GP1BA Protein
Catalog No: CD42B-HF001
- Species
- Human
- Expression System
- HEK293
- Tag
- an hFc (IgG1)
- Activity
- Activity verified
Product overview
Recombinant Human CD42b/GP1BA Protein is expressed in HEK293 cells with an hFc (IgG1) tag at the C-terminus. It contains amino acid residues His17-Leu531 (UniProt accession: P07359).
Product Details
- Molecular Aliases
- GP-Ib alpha; GPIb-alpha; GPIbA; GP1BA; BDPLT1; BDPLT3; BSS; CD42B; CD42b-alpha; DBPLT3; GP1B; VWDP; BP1BA; MGC34595
- Protein Length
- His17-Leu531
- Expression System
- HEK293
- Theoretical Molecular Weight
- The protein has a predicted MW of 82.47 kDa. Due to glycosylation, the protein migrates to 130-170 kDa based on Bis-Tris PAGE result.
- Purity
- > 95% as determined by Bis-Tris PAGE > 95% as determined by HPLC
- Endotoxin
- Less than 0.1 EU per μg by the LAL method.
- Buffer / Formulation
- Lyophilized from 0.22 μm filtered solution in PBS, 100mM L-Arginine (pH 7.4). Normally 8% trehalose is added as protectant before lyophilization.
- State
- Lyophilized
- Storage Conditions
- -20 to -80°C for 12 months as supplied from date of receipt. -80°C for 3 months after reconstitution. Recommend to aliquot the protein into smaller quantities for optimal storage. Please minimize freeze-thaw cycles.
- Reconstitution Advice
- Dissolve the lyophilized protein in distilled water. Please refer to the Certificate of Analysis for detailed instructions.
Data Display

Human CD42b on Bis-Tris PAGE under reduced condition. The purity is greater than 95%.

The purity of Human CD42b is greater than 95% as determined by SEC-HPLC.

Immobilized Human CD42b, hFc Tag at 0.5μg/ml (100μl/well) on the plate. Dose response curve for Anti-CD42b Antibody, hFc Tag with the EC50 of 21.1ng/ml determined by ELISA. (QC Test)
Background
Absence of the CD42 complex leads to the Bernard-Soulier syndrome (BSS), which is a bleeding disorder characterized by thrombocytopenia and giant platelets. So far, mutations have been found in the genes encoding CD42a, CD42b and CD42c in patients with BSS**.
References
- Clemetson KJ,McGregor JL,James E,Dechavanne M,Luscher EF Characterization of the platelet membrane glycoprotein abnormalities in Bernard-Soulier syndrome and comparison with normal by surface-labeling techniques and high-resolution two-dimensional gel electrophoresis. J Clin Invest 1982 70:304 Note: HPLC results always come from liquid protein, due to absorption peak interference of trehalose in lyophilized powder.